Open Circuit Termination Series

Open Circuit Termination Series

Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.

Specifications

Frequency Range

Reflection Coefficient

DC to 50 GHz

0.98 to 0.995

 

Features & Benefits

  • Calibration-grade metrology standards
  • Used for VNA calibration and/or calibration validation

Filters

Connector 1

Frequency Range (GHz)

Gender 1

Reflection Coefficient

Name Connector 1Frequency Range (GHz)Gender 1Reflection Coefficient
2616D4 7mmDC-18Female0.995
2616F1 7mmDC-18Female0.995
2948A TNCDC-18Female0.98
2948B TNCDC-18Male0.98
371N2 BNCDC-10Female0.98
371P2 BNCDC-10Male0.98
7948A2 2.4mmDC-50Female0.98
7948B2 2.4mmDC-50Male0.98
8048A6 3.5mmDC-26.5Female0.98
8048B6 3.5mmDC-26.5Male0.98
8585A1 BNC 75ΩDC-12Female0.98
8585B1 BNC 75ΩDC-12Male0.98
8773A1 2.92mmDC-40Female0.98
8773A4 2.92mmDC-40Female0.98
8773B1 2.92mmDC-40Male0.98
8773B4 2.92mmDC-40Male0.98
8809B2 Type NDC-18Female0.99
8810B2 Type NDC-18Male0.99
Explore More

Related Resources

01

Characterizing Uncertainty in S-Parameter Measurements

As technologies evolve and requirements become more challenging, implementing processes that increase confidence in measurements and ensure accurate and reliable characterization—and product performance—are critical. Learn how to characterize uncertainty with S-parameter measurements in this application note.

02

Improving Calibration Accuracy and Speed with Characterized Calibration Standards

This application note explains the lesser known characterized SOLT calibration which drives the means to meet the objective of faster, accurate and wide-band calibrations.

03

An Improved VNA Calibration and Validation Method for Increased Confidence in Measurements

In this video, learn how Insight uses characterized device (CD) VNA calibration kits and verification kits objectively qualify a VNA calibration and determine whether the calibration needs to be repeated.

Ready to accelerate design cycles and enhance your product's performance?

Request a Demo



 

Request a Quote



 

Request a Demo